Climatech wine room cooling system

Climatech Specifications

Below is a chart to help you determine which Climatech wine cooling system is the right choice for your commercial application. Please contact us if you have any questions.



View Climatech Pricing Guide

Model Number 3000 5000
8000
15000
Dimensions (width x depth x height) 35” x 14” x 14” 39” x 22 ” x 14” 39” x 22 ” x 14” 43” x 22 ” x 18”
Performance
Nominal Tonnage Ton 1/4 1/2 1 2
Nominal Compressor HP 1/3 1/2 1 2.5
Net Cooling Capacity*
@ 70° F Ambient BTUH 3300 / 3650 5600 / 6050 8400 / 9100 16200 / 17750
@ 80° F Ambient BTUH 3000 / 3300 5300 / 5700 7800 / 8450 15200 / 16650
@ 90° F Ambient BTUH 2800 / 3050 4850 / 5275 7300 / 7900 14100 / 15350
Net Cooling Volume Cu. Ft. < 800 801 - 1800 1801 - 4000 4001 - 8400
Controls
Type Room mounted non-programmable thermostat
Accuracy ± 2°F
Evaporator Section
Fan Motor Size Watts 75 100 195 240
Rated Air Flow CFM 235 435 510 740
Air Flow with 25’ flex duct CFM 207 400 485 715
Condenser Section
Fan Size Watts 75 100 195 240
Rated Air Flow CFM 253 400 500 750
Air flow with 25’ flex duct CFM 220 365 475 720
Heat
Type Integral electric heater coil
Capacity Watt / BTUH 1000 / 3413 1000 / 3413 2000 / 6826 2000 / 6826
Temperature rise - including fan Deg° F 13.5 8.6 12 8.1
Humidifier
Type   Removable drip pad with integral fan
Supply water temp of 60 Deg F gal./day 1.6
Supply water temp of 90 Deg F gal./day 3.5
Supply water temp of 120 Deg F gal./day 5.1
Control   Cellar mounted digital humidistat
Electrical Requirements
Power Requirements V/P/H 115/1/60 115/1/60 230/1/60 230/1/60
Current Draw - Cooling mode Amps 8.6 11.9 9.0 16
Current Draw - Heating mode Amps 9.4 9.6 9.6 10
Minimum Circuit Size Amps 15 15 15 20
Optional Low Ambient Amps 0.4 0.4 0.2 0.2
Optional Humidifier Amps 0.3 0.3 0.2 0.2
Cabinet
Construction .063 Aluminum
Finish Black, Powder Coat, Corrosion Inhibiting
Weight (lbs) 80 125 145 195
Dimensions (inches) Length 35 39 39 39
Width 14 22 22 22
Height 14 14 14 14
Condensate Drain 0.5" ID
1. Net cooling capacity at cellar temp. & humidity of 55° F & 60 % RH / 60° F & 60% RH and at rated airflow. Reduce capacity by 3% for each 10% reduction in either condenser or evaporator airflow, 5% for both.
2. Vigilant, Inc. reserves the right to make changes to this document without prior notice at its sole discretion.
3. All ratings recorded at sea level.
Recommended Insulated Flexible Ductwork Sizing Chart
  Evaporator (cooling) Coil Condenser (heat rejection) Coil
Model #
  Inlet (return air) Outlet (supply air)   Inlet Outlet
 
  Single Double   Single Double
3000 8" 8" 6" 8" 8" 6"
5000 10" 10" 6" 10" 10" 6"
8000 10" 10" 8" 10" 10" 8"
15000 12" 12" 10" 12" 12" 10"
Notes: Do not exceed a total of 25' for each length of ductwork run
1. The above referenced sizes are internal diameter in inches.
2. If a single supply is used out of the unit but then splits into two (2) ducts, the above size recommended for double is used after the split.